DeutschEnglishSpanishFrenchItalian
CPC XL INOX

Evacuated tube collectors CPC XL INOX

  • Pipe material: stainless steel
  • Colour of aluminium frame profile, powder-coated: RAL 7015

Mounting types:

  • Roof mounting
  • Flat roof/wall mounting

All collectors

Series   CPC 6 XL INOX CPC 12 XL INOX
Number of evacuated tubes  6 12
collector energy output scale (50°C/75°C) (Solergy) 1)   AA/AA AA/AA
collector energy output (50 °C Würzburg) kWh/ year 855 1703
energy output per collector module 2) W 782 1558
energy output per collector module 3) W 831 1655
product data according to Commission Regulation (EU) No 811/2013 and 812/2013 (Erp-relevant Data) regarding aperture area
Asol collector aperture area m2 1.29 2.57
η0 zero-loss efficiency   0.644 0.644
ηcol collector efficiency % 61 61
a1 first-order coefficient W/(m² K) 0.75 0.75
a2 second-order coefficient W/(m² K²) 0.005 0.005
IAM incidence angle modifier   1.00 1.00
 
other product details
gross area 1.45 2.87
collector dimensions (length x width x height) m 2.06 x 0.71 x 0.10 2.06 x 1.40 x 0.10
collector contents l 1.06 2.11
weight of empty collector kg 21.1 39.9
max. operation pressure bar 10 10
max. stagnation temperature °C 301 301
connection-diameter, compression fitting mm 15 15
sensor sleeve mm 6 6
colour (aluminium frame profile, anodized)   RAL 7015, powder-coated
colour (plastic parts)   black
conformity 4)   Pressure Equipment Directive 2014/68/EU
impact resistance test according to ISO 9806 mm 35
tests and licence   ISO 9806, Solar Keymark
DIN CERTCO-licence number   011-7S134R
1) usable only with own Solar Keymark certification, details refer: www.solar-heating-initiative.com and www.dincertco.de.
2) At 1000 W/m² and 40 K temperature difference between the average collector temperature and ambient temperature.
3) At 1000 W/m² and 0 K temperature difference between the average collector temperature and ambient temperature.
4) existing certification of collectors by TÜV SÜD Industrie Service GmbH for Ritter Energie- und Umwelttechnik GmbH & Co.KG; Validity within Germany. A separate certification according to Pressure Equipment Directive can be applied for at TÜV when needed.

Pressure loss of the Ritter Gruppe evacuated tube collectors CPC 6/12 XL INOX

  • Heat distribution medium: Tyfocor LS, medium temperature 40°C
pressure loss of the tube collectors

Power curve of the Ritter Gruppe evacuated tube collectors CPC 6/12 XL INOX

  • (G = 1,000 W/m²)
Power curve
CPC 6 XL INOX
CPC 6 XL INOX
CPC 12 XL INOX
CPC 12 XL INOX